Fire Alarm Kits and Accessories from ESP Fireline
|
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
 |
|
|
|
|
2 Zone Metal Fire Panel, Upto 30 Detectors per zone, Unlimited Call Points Per Zone, 2 Sounder Outputs, Fault & Aux Relay Outputs, One Man Test Feature, Active End of Line Monitoring, CE Certified and Complies with BS 5839 & EN 54. Approximate Size W200mm x H290mm x D80mm.
Kit Contains:- 1x 2 Zone Control Panel End Station, 2x Combined Optical / Heat Detectors, 2x Smoke Detector Bases, 1x Manual Call Point, 1x Internal Electronic Sounder, 1x 100 meter Drum of Fire Resistant Cable, 1x System Rechargeable Battery, 1x Pack of Cable Clips.
|
|
|
|
 |
|
|
|
|
4 Zone Metal Fire Panel, Upto 30 Detectors per zone, Unlimited Call Points Per Zone, 2 Sounder Outputs, Fault & Aux Relay Outputs, One Man Test Feature, Active End of Line Monitoring, CE Certified and Complies with BS 5839 & EN 54. Approximate Size W200mm x H290mm x D80mm
Kit Contains:- 1x 4 Zone Control Panel End Station, 6x Combined Optical / Heat Detectors, 6x Smoke Detector Bases, 2x Manual Call Point, 1x Internal Electronic Sounder, 1x 100 meter Drum of Fire Resistant Cable, 1x System Rechargeable Battery, 1x Pack of Cable Clips.
|
|
|
|
|
 |
|
|
|
|
The MAG Fire Alarm Centre has been carefully designed to answer the rigorous demands of specifiers, installers and users, simplicity itself to install, program and expand. For users, the MAG Alarm Centre's confusion free instructions are clear and easy to understand and follow.
2 programmable zones, Activate end of line monitoring, 30 fire detectors per zone, Unlimited number of call points per zone, Integral manual alarm button, ‘Class change' facility, Enable/disable security key, one man walk test facility, Fire volt free change over relay, Fault volt free change over relay, Individual sounder circuit fault ID, Individual zone/sounder isolate, BS5839 and EN54 compliant, CE certified. Requires only 1x12v battery (not supplied). Metal casing. Approximate Size W200mm x H290mm x D80mm.
|
|
|
|
|
 |
|
|
|
|
The MAG Fire Alarm Centre has been carefully designed to answer the rigorous demands of specifiers, installers and users, simplicity itself to install, program and expand. For users, the MAG Alarm Centre's confusion free instructions are clear and easy to understand and follow.
4 programmable zones, Activate end of line monitoring, 30 fire detectors per zone, Unlimited number of call points per zone, Integral manual alarm button, ‘Class change' facility, Enable/disable security key, one man walk test facility, Fire volt free change over relay, Fault volt free change over relay, Individual sounder circuit fault ID, Individual zone/sounder isolate, BS5839 and EN54 compliant, CE certified. Requires only 1x12v battery (not supplied). Metal casing. Approximate Size W200mm x H290mm x D80mm.
|
|
|
|
|
 |
|
|
|
|
Conventional Combined Optical & Heat Detector with Base - The new range of Fireline detectors have been developed to provide a perfect compliment to the Fireline Mag panels. All detectors are supplied with a diode base, and conform to the latest EN54 standards. Their smooth aesthetics and competitive pricing will make them more than suitable for the majority of conventional installations.
Dimensions 106 (diameter) x 48(h) mm, Level of protection IP-40, Magnetic Test Facility.
|
|
|
|
|
 |
|
|
|
|
Conventional Optical Detector with Base - The new range of Fireline detectors have been developed to provide a perfect compliment to the Fireline Mag panels. All detectors are supplied with a diode base, and conform to the latest EN54 standards. Their smooth aesthetics and competitive pricing will make them more than suitable for the majority of conventional installations.
Dimensions 106 (diameter) x 48(h) mm, Level of protection IP-40, Magnetic Test Facility.
|
|
|
|
|
 |
|
|
|
|
Fixed Heat Detector with Base - The new range of Fireline detectors have been developed to provide a perfect compliment to the Fireline Mag panels. All detectors are supplied with a diode base, and conform to the latest EN54 standards. Their smooth aesthetics and competitive pricing will make them more than suitable for the majority of conventional installations.
Dimensions 106 (diameter) x 48(h) mm, Level of protection IP-40, Magnetic Test Facility.
|
|
|
|
|
 |
|
|
|
|
Conventional Rate of Rise Heat Detector with Base - The new range of Fireline detectors have been developed to provide a perfect compliment to the Fireline Mag panels. All detectors are supplied with a diode base, and conform to the latest EN54 standards. Their smooth aesthetics and competitive pricing will make them more than suitable for the majority of conventional installations.
Dimensions 106 (diameter) x 48(h) mm, Level of protection IP-40, Magnetic Test Facility.
|
|
|
|
|
 |
|
|
|
|
Surfacing mounting call point
A surface mounting call point built and designed to latest EN54 standards.
|
|
|
|
|
 |
|
|
|
|
Flush mounting call point
A flush mounting call point built and designed to latest EN54 standards.
|
|
|
|
 |
|
|
|
|
Replacement glass for manual call points. Pack of 10.
|
|
|
|
|
 |
|
|
|
|
Banshee electronic sounder, Maximum output 103db, Operating voltage 24V DC, Current consumption 17mA, Level of protection IP-45. Available in Red or White.
|
|
|
|
|
 |
|
|
|
|
Multi Alert electronic sounder, User selectable tones, Maximum output 103db, Operating voltage 24V DC, Current consumption 18ma, Level of protection IP-44. Supplied with base.
|
|
|
|
|
 |
|
|
|
|
Mechanical 6” Fire Bell for internal use, Maximum output 95db, Operating voltage 24V DC, Current consumption 11ma, Level of protection IP-55 (TBC).
|
|
|
|
|
 |
|
|
|
|
Weatherproof Mechanical 8” Fire Bell for external use, Maximum output 95db, Operating voltage 24V DC, Current consumption 25ma, Level of protection IP-55 (TBC).
|
|
|
|
|
 |
|
|
|
|
Banshee Combined electronic sounder & strobe, Sound output 103db, Strobe output 2 watt, Flash rate 1 per second, Current consumption 101ma, Operating voltage 24V DC, Level of protection IP-66.
|
|
|
|
|
 |
|
|
|
|
2-watt strobe, Flash rate 1 per second, Current consumption 84ma, Operating voltage 24V DC.
|
|
|
|
|
 |
|
|
|
|
Magnetic door holder, Supplied with a surface mounting box, Manual release button mounted on surface of the box, built in release spring, Supplied with a swivel keeper plate. Available in 24VDC or 240VAC
|
|
|
|
|
 |
|
|
|
|
Floor Mounting Bracket for Door Holders
|
|
|
|
|
 |
|
|
|
|
Spare door keeper plate
|
|
|
|
|
 |
|
|
|
|
|
Boxed 24VDC Power supply unit, 1 Amp, battery monitoring facility, Mains supply 230V/240V 50Hz, Maximum battery size 2 x 12 V Rechargeable 7Ah batteries, Total output 1Amp at 27.6V DC, Approximate size 275(h) x 330(w) x 80(d) mm
|
|
|
|
|
 |
|
|
|
|
Boxed 24VDC Power supply unit, 2 Amp, battery monitoring facility, Mains supply 230V/240V 50Hz, Maximum battery size 2 x 12 V Rechargeable 7Ah batteries, Total output 2Amp at 27.6V DC, Approximate size 275(h) x 330(w) x 80(d) mm
|
|
|
|
|
 |
|
|
|
|
Boxed 24VDC Power supply unit, 3 Amp, battery monitoring facility, Mains supply 230V/240V 50Hz, Maximum battery size 2 x 12 V Rechargeable 7Ah batteries, Total output 3Amp at 27.6V DC, Approximate size 275(h) x 330(w) x 80(d) mm
|
|
|
|
|
 |
|
|
|
|
Fire resistant cable for fire alarms, 2 core 1.5mm and earth, Supplied on 100 metwr reels. Designed to meet all relevant standards.
|
|
|
|
|
 |
|
|
|
|
Rechargeable sealed lead acid battery, Capacity 7.0Ah, 12 Volt DC, Suitable for fire alarm systems.
|
|
|
|
|